Dave,

I like that answer, I have even chased it before... Epoxy, pigmentless
appears as non wetting.  Would explain one side.  The supplier should 'fess
up to other same time part numbers having similar problems.  This is either a
process problem at PCB supplier, problem due to the complexity of PCB itself
(during the bare part fab), process problem at assy or alas... OE   (Operator
Error).  Sounds like a tuff nut to crack.

Boston Brad

---------------------------------------------------------------------------------