TECHNET Archives

March 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum.
Date:
Mon, 11 Mar 2002 11:32:07 EST
Content-Type:
text/plain
Parts/Attachments:
text/plain (34 lines)
Hello...

Wait, wait and wait...  I am no advocate of CIC, but Thermount does have its
flaws.  The attractive low CTE in the nonwoven configuration takes on similar
CTE properties as adjacent copper planes, negating much if not all its CTE
advantages.  Conservative design criteria must me employed due to the
.003-.007 Kevlar fibers and their resistance to drilling.  This resistance
has them pullout of drilled holes giving the PTH a much more "leaching"
appearance.  These copper fingers horizontally extending to opposite polarity
planes is reason for concern.  Add to this the moisture absorption and there
is real "potential" trouble in HDI type packaging (pun intended).  The "BI"
(and even BF) material has a difficult and challenging time passing the
stringent moisture acceptance criteria of boards.  My advice I hand out for
Thermount Customers is watch out for PTH to plane clearances, don't go below
8 and 8, and don't place planes directly below SMT layers (i.e. layer two).
From a bare board fab perspective the layer stability is somewhat erratic and
not stable registration as it was thought.

Every material and configuration is application specific.

Boston Brad
781 858 0783

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2