Hi MoonMan, Peter, et al,
In a message dated 03/07/2002 0:38:57, [log in to unmask] writes:
>Actually, instead of more discussion on my part, IPC 2221, etc., and 6012
>cover all the ground, and much more, you are concerned about. There's
>little else to say.
Well, that is not quite accurate, neither document adequately addresses the
reliabiliity issues--for that you need to go to IPC-D-279.
IPC-D-279 also will help you correlate some of the info; additional helpcan
be found in IPC-TR-486 and IPC-TR-579.
Any copper barrel plating thickness below 1.0 mils should be considered
especially vulnerable.
Werner Engelmaier
---------------------------------------------------------------------------------