TECHNET Archives

February 2002

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Reply To:
TechNet E-Mail Forum.
Date:
Tue, 26 Feb 2002 12:51:18 -0600
Content-Type:
text/plain
Parts/Attachments:
text/plain (33 lines)
Jim Jenkins nervously writes:

I was just approached by one of our engineers whose customer told her that
the Air Force has issued a directive disallowing the use of no-clean fluxes
on any of their hardware.  The customer is flowing down that requirement to
us.  Do any of you know of this directive or what they could be referring
to?

Doug Pauls, ever calm and collected, responds.

Jim, this is the first I have heard of anything along these lines and we
build LOTS of stuff for the Air Force.  On the other hand, we clean our
hardware, so they may not feel the need to talk to us on this issue.  I
would think that levying such a requirement on *existing* hardware would be
next to impossible since you affect thousands of contracts.  You might want
to determine if this is a requirement for NEW designs.  Since many
companies do manufactur hi-rel equipment with no-clean processes, I would
be curious as to the technical rationale for such a requirement.

Doug Pauls
Rockwell Collins

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2