Hi Richard,

It depends on the actual component dimensions and pinouts.  Sometimes it
works out, sometimes it doesn't.  Unfortunately, not all component
manufacturers mean the same thing when they say "SO" and "SOP".  If you'd
like to send me drawings and pinouts of the two packages (or at least a full
manufacturer's part number for each), I'd be happy to look them over.

Something to consider is that if the pads from one component are under the
body of the other and there is not much standoff height, I could imagine
some trouble.  If this is indeed a problem, you would need a separate
stencil for each variant of the assembly.

Regards,

Seth Goodman
Goodman Associates, LLC
tel 608.833.9933
fax 608.833.9966


> -----Original Message-----
> From: TechNet [mailto:[log in to unmask]]On Behalf Of Richard Hawkins
> Sent: Wednesday, February 20, 2002 10:57 AM
> To: [log in to unmask]
> Subject: [TN] pads for so package and sop package?
>
>
> I have a situation in which my company wishes to "dual source" an IC, the
> only catch is that one is an so package and the other is a sop package.
>
> This is a new problem for me.  I am looking to the experience and
> expertise
> of this list to help me come to the correct answer for my company.
>
> Any advise/opinion/experience will be appreciated.
>
> TIA
>
> Sincerely,
>
>
> Richard Hawkins
>
> ------------------------------------------------------------------
> ---------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to
> [log in to unmask]: SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
> [log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources &
> Databases > E-mail Archives
> Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> information, or contact Keach Sasamori at [log in to unmask] or
> 847-509-9700 ext.5315
> ------------------------------------------------------------------
> ---------------
>

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2