I think the problem you will find as was explained before is the cost of
these liquids are very pricey and they only make them a few times a year
and if they have non and you want some you will have to wait.   Just my two
cents worth.



                    Jim Kittel
                    <[log in to unmask]       To:     [log in to unmask]
                    -3COM.COM>           cc:
                    Sent by:             Subject:     Re: [TN] Antw: [TN] Vapor Phase
                    TechNet               Soldering ReVisited!
                    <[log in to unmask]
                    RG>


                    02/14/02 12:59
                    PM
                    Please respond
                    to "TechNet
                    E-Mail
                    Forum.";
                    Please respond
                    to jkittel






Guenter,
Thanks for your response.  I also had trouble finding a liquid with a
boiling point of 225, but according to an article mentioned earlier (
www.assemblymag.com ) the liquids of different boiling points can be
blended
to achieve what you need.
Thanks,
Jim Kittel

-----Original Message-----
From: Guenter Grossmann [mailto:[log in to unmask]]
Sent: Thursday, February 14, 2002 9:44 AM
To: [log in to unmask]
Subject: [TN] Antw: [TN] Vapor Phase Soldering ReVisited!


Jim

I believe the VP is still a good principle. However, the industrial partner
in LEADFREE that runs the VP trials told me that he has to use a liquid
with
a boiling point of 270 deg.C and that there is nothing available that boils
around 230 deg.
I had problem to believe this but also after asking again I got the same
answer.

Best regards

Guenter

.

EMPA
Swiss Federal Institute for Materials Testing and Research
Centre for Reliability
Dipl. Eng. Guenter Grossmann

8600 Duebendorf
Switzerland

Phone: xx41 1 823 4279
Fax :     xx41 1823 4054
mail:     [log in to unmask]

----------------------------------------------------------------------------

-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
SET
Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------

-----

---------------------------------------------------------------------------------

Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2