Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Fri, 1 Feb 2002 17:37:32 -0700 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
Please, no "square pegs in round hole" jokes!!
David A. Douthit
Manager
LoCan LLC
"Reid, Lorraine" wrote:
> Can anyone point me in the direction of any investigations into the
> potential for long term failures caused by inserting a thru-hole mounted
> connector into holes which are slightly too small to fit?
>
> We have a situation where a connector, with square pins, diagonal
> dimension 25 thou, is being inserted into plated holes, finished size 22
> thou. The connector is then soldered. The connector pins can be
> forced in, but I am concerned about the potential for damage that may
> not appear immediately obvious. The board is 4 layer, so obviously
> there are connections from the holes to the inner layers. The obvious
> solution is to enlarge the holes (not possible for this batch), but the
> designer is unwilling to make changes unless we can prove that there is
> a genuine risk of failure of the interconnects due to forcing the
> connector into the board.
>
> Thanks in advance
>
> Lorraine Reid
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|