OK, here is the background on this particular dendrite growth:

It is a field failure unit and upon closer inspection, this dendrite
follows a crack in the capacitor from one termination to the other.  In my
opinion, the crack was there first, and was filled with contaminated
moisture while the cap had battery voltage (5V) across it, causing the near
perfect dendrite to form along the walls of the crevice.

This CCA was produced on our no clean assembly line, of which the
cleanliness is monitored on each lot of boards produced.  We believe that
the solder flux residues are not related to this defect.  The soldering
residues do not migrate to this area of the capacitor.

The condensation moisture alone would not seem to be enough to have
generated this dendritic growth so we are investigating other possible
contamination that may have been present such as moisture dripping off of a
dirty shelf above, and also the component cleanliness itself.  If the crack
was there from the beginning then the contamination could have been as well.

We have seen shorts across this capacitor before but usually only as random
faint carbon tracks that are nowhere as defined as this one was.

This one is so perfect, it almost looks like an organic plant like a small
fern.

This is an ongoing investigation so all comments are welcome and I will
provide an update at some point in the future.

Phil


At 06:51 AM 2/25/02 -0700, [log in to unmask] wrote:
>Doug,
>Isn't that known as the Mountain "Dew"lution Test?
>Dewey
>
> > -----Original Message-----
> > From: [log in to unmask] [SMTP:[log in to unmask]]
> > Sent: Monday, February 25, 2002 6:31 AM
> > To:   [log in to unmask]
> > Subject:      Re: [TN] Dendritic Growth...
> >
> > Sunny asks:
> >  I'd like to know which type of Ion Chromatography can measure the local
> > dot ionic cleanliness.  Anyone can tell me which company produce this
> > equipment?
> >
> > Doug Pauls responds:
> >
> > No company that I know of builds ion chromatography equipment to do spot
> > ionic checks.  IC equipment merely analyzes extract solutions.  If you
> > want
> > to measure localized ion concentrations, you have to develop a localized
> > extraction technique.  This might involve immersion of a portion of the
> > assembly in extract solution, or building some time of non-contaminating
> > enclosure around the area to be extracted.  Once you can localize the
> > extraction, collect the solution an analyze it with the IC equipment
> >
> > --------------------------------------------------------------------------
> > -------
> > Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> > To unsubscribe, send a message to [log in to unmask] with following text in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
> > SET Technet NOMAIL
> > To receive ONE mailing per day of all the posts: send e-mail to
> > [log in to unmask]: SET Technet Digest
> > Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> > E-mail Archives
> > Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
> > information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> > ext.5315
> > --------------------------------------------------------------------------
> > -------
>
>---------------------------------------------------------------------------------
>Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
>SET Technet NOMAIL
>To receive ONE mailing per day of all the posts: send e-mail to
>[log in to unmask]: SET Technet Digest
>Search previous postings at: www.ipc.org > On-Line Resources & Databases >
>E-mail Archives
>Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
>ext.5315
>---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2