I do not think these are ozone depleter but they are very costly.
This is the statement that they give regarding there material
in the data you are talking about.
Hence, Fomblin and Galden perfluoropolyether fluids have a ZERO
Ozone Depletion Potential and are not classified as VOCs by the
EPA.
Brian Ellis
<b_ellis@PROTO To: [log in to unmask]
NIQUE.COM> cc:
Sent by: Subject: Re: [TN] Antw: [TN] Vapor Phase
TechNet Soldering ReVisited!
<[log in to unmask]
RG>
02/16/02 03:01
AM
Please respond
to "TechNet
E-Mail
Forum.";
Please respond
to Brian Ellis
Guenter
See http://www.ausimont.com/docs/gald_vapor.html
This gives you details of fluids with BPs of 155, 166, 200, 210, 215,
230, 240 and 260 °C. Surely you can find one to suit almost any
application in that range.
However, I repeat my earlier warning that these products are horrific
global warmers and are not exactly given away with a packet of corn
flakes.
Best regards,
Brian
Guenter Grossmann wrote:
>
> Jim
>
> I believe the VP is still a good principle. However, the industrial
partner in LEADFREE that runs the VP trials told me that he has to use a
liquid with a boiling point of 270 deg.C and that there is nothing
available that boils around 230 deg.
> I had problem to believe this but also after asking again I got the same
answer.
>
> Best regards
>
> Guenter
>
> .
>
> EMPA
> Swiss Federal Institute for Materials Testing and Research
> Centre for Reliability
> Dipl. Eng. Guenter Grossmann
>
> 8600 Duebendorf
> Switzerland
>
> Phone: xx41 1 823 4279
> Fax : xx41 1823 4054
> mail: [log in to unmask]
>
>
---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
SET Technet NOMAIL
> To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
> Search previous postings at: www.ipc.org > On-Line Resources & Databases
> E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
>
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]:
SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site http://www.ipc.org/html/forum.htm for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|