Doug,

I believe that some suppliers of this kind of equipment have dealt
successfully with this issue (conductive media, ionisation, etc). See
http://www.ccrco.com, for example.

Regards,
Peter
--
=========================================================
Peter Swanson            [log in to unmask]
INTERTRONICS                http://www.intertronics.co.uk

INTERTRONICS is dedicated to providing quality material,
  consumable and equipment solutions to the electronics
manufacturing and other technology based industries, with
   the highest levels of technical support and customer
                         service.


-----Original Message-----
From: [log in to unmask] [mailto:[log in to unmask]]
Sent: 30 January 2002 21:27
To: [log in to unmask]
Subject: Re: [TN] Conformal Coating


Mike Sewell Suggests:   Would microabrasive blasting of the coating be an
alternative to chemical stripping?

*Just be aware that microabrasive blasting generates a hell of a static
charge.  Enough to kill a static sensitive component.  I think the EMPF did
some work in microabrasion methods relative to ESD in the late 80s early
90s.  Check with the librarian at www.empf.org.

Doug Pauls
Rockwell Collins

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2