Use a hydrometer and a large vial. We fill the vial up and then put the hydrometer into the solution. We can then tell specific gravity from that and we may possibly thin or add more flux depending on the reading. We use the acceptable ranges per the flux manufacturer. Record the results of the readings and the actions taken. This info is extremely important and wil give you some very good trend analysis.