Can someone/anyone please send me or direct me to a study that concluded
that removing "a land that is not connected electrically to the conductive
pattern on its layer" decreased reliability in any way?  How about a study
that concluded a maintained or increased reliability by keeping or adding
non-functional pads?  ...I cannot find anything in the IPC specifications
discouraging the removal of non-functional pads.

From practical fabrication experience, removing a non-functional pad does
provide benefits:
1) It is easier to drill through less copper, causing less wear on the bit,
thereby increasing the potential quality of the hole.
2) Most importantly, removing the pads does not change connectivity but does
reduce/eliminate a real potential to short to adjacent connections.

Other effects:
1) Apparently, removing all non-functional pads within the via reduces the
overall capacitance of the via (see
http://www.qsl.net/wb6tpu/si-list/0687.html).
2) For some non-plated holes, if the pads are left on and it is drilled
after etch, the land/pad may be ripped off of the surface if there is not
enough ring to anchor the pad.  This only happens on the outer layers.
3) For some applications, a land may be used to anchor the hole connection
to the material (PTFE, flex)
4) Are there other effects?  Thermal, impedance, pth reliability?




-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Hinners Hans M Civ
WRALC/LUGE
Sent: Tuesday, January 15, 2002 8:41 AM
To: [log in to unmask]
Subject: Re: [TN] Remove unused "dead" pads on internal layers


Hi Patrick,

As others have said, I don't think the class of board matters for "unused"
pads.  It all depends on what your procurement documentation states, are you
building to drawing or is there a clause that says process improvements that
do not affect functionality are permissible.

"Are they really unused pads?"

They may be electrically nonfunctioning but they are there for a reason -
better lamination quality (avoiding low pressure areas or excessive prepreg
flow), better hole wall quality, better plating quality (esp. for any
isolated traces), reduced loading of your etch solution or better thermal
loading during assembly.

Hans

Integrity First  -  Service Before Self  -  Excellence in All We Do
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Hans M. Hinners
Electronics Engineer
Warner Robins - Air Logistics Center (WR-ALC/LUGE)
226 Cochran Street
Robins AFB GA 31098-1622

mailto:[log in to unmask]

Com: (478) 926 - 5224
Fax:   (478) 926 - 4911
DSN Prefix: 468


-----Original Message-----
From: Patrick Lam [mailto:[log in to unmask]]
Sent: Friday, January 11, 2002 5:12 PM
To: [log in to unmask]
Subject: [TN] Remove unused "dead" pads on internal layers


Hi TechNetters,

For class 3 boards, is it acceptable to have unused pads removed on
interanal
layers.

Thanks,
Pat
This e-mail may contain SEL confidential information.  The opinions
expressed
are not necessarily those of SEL.  Any unauthorized disclosure, distribution
or
other use is prohibited.  If you received this e-mail in error, please
notify
the sender, permanently delete it, and destroy any printout.  Thank you.

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET
Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to
[log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send e-mail to [log in to unmask]: SET Technet NOMAIL
To receive ONE mailing per day of all the posts: send e-mail to [log in to unmask]: SET Technet Digest
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2