TECHNET Archives

December 2001

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Leo Lambert <[log in to unmask]>
Reply To:
Date:
Tue, 18 Dec 2001 09:42:59 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (54 lines)
The damage laminate can be found in 600 under 2.2.3 Exposed/disrupted
Fibers. Exposed or disrupted fiber areas are considered conductive area and
if they reduce the minimum electrical spacing requirements, they are
nonconforming and must be repaired. IPC 6012, 3.3.2.2 Weave Exposure also
discussed the condition.

Hope this helps

Leo Lambert
EPTAC Corp
[log in to unmask]


-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Shawn Murphy
Sent: Monday, December 17, 2001 6:32 PM
To: [log in to unmask]
Subject: [TN] Trace cut quality


What specification would contain "Trace Cut" information?  We have a
situation where there is obvious damage to the FR4 material between two
leads that had a common trace at one point.  Our conscious tells us to
repair the gouge but we haven't located anything in IPC-610 to tell us what
is acceptable and what isn't.  Any help would be greatly appreciated.

regards,
shawn

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2