Dan,
The rule of thumb that I had heard from a solder paste application engineer
was that you should be able to fit 8 solder balls across your smallest
aperture width.
I am not sure your 0201 solder paste aperture will work very well (unless
you made a typo). .13mm x .26mm is really, really small. If your foil size
is .076mm
(.003") or greater, your aspect ratio is below .6
You really need to be around .3mm x .35mm or .34mm square if your foil size
is .13mm. This puts your AAR over .66
Steve A
> -----Original Message-----
> From: Dan R. Johnson [SMTP:[log in to unmask]]
> Sent: Thursday,December 20,2001 8:19 AM
> To: [log in to unmask]
> Subject: Re: [TN] mesh size
>
> Thanks John, this confirms what I thought. I don't know if you could say
> the aspect ratio is "right" but I am using a .13X.26mm paste pad. This is
> an Rf application and the design engineer is adamant that all component
> pads be as small as possible.
> You mentioned the ball size to aperture size ratio, is there a "rule of
> thumb" for this?
> Dan
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|