Hi Ray,

The formula you are looking for is A1v1=A2v2 where A is the cross-sectional
area and v is the speed.

BTW,  your physical principles are slightly incorrect.  Liquids don't expand
or compress. (with exception of extreme pressures and CTE expansion)
Bernoulli's equation is P+(1/2)pv^2+pgy=C, while fundamental to fluid
dynamics, I'm not sure it will help in this case.

Kind Regards

Ryan Grant
Advanced Technology Engineer
MCMS
(208) 898-1145
[log in to unmask]


> -----Original Message-----
> From: Golembiewski, Ray [SMTP:[log in to unmask]]
> Sent: Monday, November 12, 2001 12:34 PM
> To:   [log in to unmask]
> Subject:      [TN] Formula?
>
>         What is the formula that proves when I put my thumb on the end
> of a garden house, the pressure increases and volume decreases. Is the
> same formula used with air? Please help,
>
> Ray Golembiewski C.I.D.
> Manufacturing Test Engineer
> Projects Unlimited, Inc.
> (937) 918-2200
>
> --------------------------------------------------------------------------
> -------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET
> Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> --------------------------------------------------------------------------
> -------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2