Hello Technet
A question for bare board gurus.   Is there a difference in reliability between high Tg and regular Tg FR-4 ( IPC-4101/24 vs IPC-4101/21) in a vehicle type application?
The end use application is less than Tg of /21 material, so not in the glass transition range for either material.

Typically - is the CTE different between these two?  (I expect that depends on the manufacturer to some degree).  If there isn't a high temperature operating requirement, why select the high temp FR-4?

Thanks!



regards

Graham Collins
Process Engineer, 
Northrop Grumman
Atlantic Facility of Litton Systems Canada
(902) 873-2000 ext 6215

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2