We have done boards with BGA's on both sides, but not in mirrored
positions, for the very reason you point out - the difficulty in X-raying
them. You will probably get a result on one side only, by X-raying one side
before populating the other.

Or you can point out the problem to your potential customer and see if they
can re-route the card to avoid this. Either that or find out if the
inspection problem is a concern to them (it should be, even though I've
found most X-rays to be pretty inconclusive as a means of determining how
well assembled the BGA's are).

As for applying epoxy to the components, unless you use a no-flow type
underfill that also acts as a fluxing agent in the assembly, you have no
other means of bonding unless you bond the corners of the BGA's fitted and
x-rayed after the first soldering pass. How big are the BGA's? It's
possible that they're light enough for surface tension to hold them in
place while up-side down during the second solder pass without them falling
off. Steve Gregory, I think it was, once gave a figure of how much weight
per contact can be held in place by surface tension of molten solder - was
it 5 grams per contact? But I don't know if this figure can be applied to
BGA's with their all-solder contacts. The effects of gravity and other
forces may distort the solder joints' form enough to reduce their
reliability.

My tuppence worth (UK value), but hope it helps a little.

Peter Duncan




                    Larry Koens
                    <lwkoens@EIMI        To:     [log in to unmask]
                    CRO.COM>             cc:     (bcc: DUNCAN Peter/Asst Prin Engr/ST
                    Sent by:             Aero/ST Group)
                    TechNet              Subject:     [TN] double sided BGAs
                    <[log in to unmask]
                    ORG>


                    10/18/01
                    12:32 AM
                    Please
                    respond to
                    "TechNet
                    E-Mail
                    Forum."






Dear TechNet,
My company has been  asked to bid on assembling a board that would have
two BGAs on the topside and two more BGAs mirrored on the bottomside.
That is, they will be directly across from each other on both sides. I
never done them on both sides. So far, everything that I have done has
been on one side only. Has anyone done them on both sides before?

  I am figuring xray will be a problem as after the second side is
placed, because the pads/balls will mirror each other on both sides.
Would I be able to tell the difference between the two BGA connections?
Suggestions?

Will I need to epoxy the first side BGAs so they would not drop off
during my second reflow? Wouldn't I need to epoxy them after first
reflow so that the balls could collapse?

Thanks,
Larry Koens
SMT Manufacturing Engineer
E.I. Microcircuits
Mankato, MN

---------------------------------------------------------------------------------

Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------





[This e-mail is confidential and may also be privileged. If you are not the
intended recipient, please delete it and notify us immediately; you should
not copy or use it for any purpose, nor disclose its contents to any other
person. Thank you.]

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2