Subject: | |
From: | |
Reply To: | |
Date: | Mon, 15 Oct 2001 11:09:33 -0700 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
PADS only allows one instance of a board outline. As to importing from
Autocad, there is an app note at
http://www.innoveda.com/support/kb/powerpcb/ApplicationNote/Creating_an_Auto
CAD_drawing_for_pcb_bga.htm
The above line will probably wrap, so use cut and paste to go to the
address.
David Ricketts
Pertek Engineering
Voice: 949-475-4485
Fax: 949-475-4493
-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of William Sullivan
Sent: Monday, October 15, 2001 9:02 AM
To: [log in to unmask]
Subject: [TN] padsPCB question
Good Morning fellow Tech Netters,,
I have a software question regarding Pads PCB,, Is there a
slick work around to generate multiple board outlines on the same
layout.. and to make things more ugly im inporting from Autocad !!!! if
not,, how can i import one set of lines into a boardout line and the
other into cutouts from Autocad at the same time ?????
Thanks Bill
William Sullivan C.I.D
SR. PCB Design Engineer
Luminent Inc
20550 nordhoff St.
Chatsworth CA, 91311
818-773-9044 EX 2114
----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|