Jeff

We have found that using a specific saponifier at 10% and a low pressure high
flood cleaning approach at 145 F works very well at removal of the low
residue (No-Clean) solderpaste residues and wave solderflux. This is done
without brushing and works with a 2-3 min wash contact timing.  We have
rescue cleaned many a board this way.  So it can be done.  Contact me offline
and I can give you the details.

Terry Munson
CSL Inc.
75-457-8095

---------------------------------------------------------------------------------