Why are you doinf high-pot testing on a PWA?  Normally all one does for PWAs
is to run an insularion resistance test at 500 VDC between isolated circuits
and between isolated circuits and ground.  You did not state your design
circuit voltage.  3KV high pot voltage is high.  Suggest that if you must do
the testing you limit the test voltage to the Table shown in MIL-E-917.
----- Original Message -----
From: "PL" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Friday, August 31, 2001 1:47 PM
Subject: Re: [TN] Hi-pot test


> Hello,
>
> Does anyone have experience in determining the root causes for hi-pot
> test failures?
>
> I am especially interested in the effect of flux residues remaining from
> no-clean hand soldering. The DUTs are being screened with a 3KV, 10sec
> hi-pot tester. So far my results are inconclusive as to whether the flux
> seen on the board has any influence on the test results.
>
>
> Rgds,
> Peter
>
>
>
> _________________________________________________________
> Do You Yahoo!?
> Get your free @yahoo.com address at http://mail.yahoo.com
>
> --------------------------------------------------------------------------
-------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
> --------------------------------------------------------------------------
-------
>

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2