>>> "May William D (Dean) CNIN" <[log in to unmask]> 09/19/01 11:17AM >>>

Reading from IPC-6012A, I noticed the required starting thickness of an
external conductor prior to plating for 1/8 oz base copper foil is 0.00020
inches and the starting thickness for 1/2 oz base copper is 0.00067 inches.
Does anyone have an idea on how minimum starting thickness is determined for
each weight of base copper?  If minimum base thickness is exceeded by
chemical milling and micro-etching processes, will it compromise board
reliability assuming that there is sufficient electroplated copper to meet
minimum total finished copper thickness? What possible problems may arise if
these base minimums are exceeded?

Thanks for your consideration!

Ed McAtee
NAVSURFWARCEN
PHONE 812-854-3892
FAX 812-854-1174

 
 

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2