>>> "Estrada, Roland" <[log in to unmask]> 09/18/01 01:37PM >>>

JESD22-B108
3.1 Seating Plane
The plane established by the contact points of three or more leads that
support the device when it is placed on top of a planar surface.
(I read this as each component will establish its own seating plane to the
board surface)

3.2 Deviation from Coplanarity
The distance between the intended contact point of a lead and the
established seating plane.
(IPC-610 should address the maximum lead offset from the pad).

4. PROCEDURE
4. Measure the deviation from coplanarity of all the leads on the device.


-----Original Message-----
From: Jack Crawford [mailto:[log in to unmask]] 
Sent: Tuesday, September 18, 2001 11:41 AM
To: [log in to unmask] 
Subject: Re: [TN] Question about Coplanarity


>>> lckang <[log in to unmask]> 09/17/01 08:48PM >>>

Hi Technetters!
      According to JESD22-B108 (complanarity test for SMD), the device's
coplanarity defined as the largest distance distance between the contact
point of leads and the established seating plane, but when the estabilished
seating plane is estabilished by three leads which are bend downwards, Is it
mean that all other device leads are out of planar position.
     So can I define it as vertical distance measured from the lowest lead?

     Thanks for your any input.

Best Regards,
Liu Changkang

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2