Hi All,
Does J-STD-006 specify the allowable contaminant levels in my HAL solder
pot?
IPC-6012A sec3.2.6.4 (Solder Coating) points to J-STD-006.
J-STD-006 sec3.2 (Alloys) shows Cu @0.08% max, which seems VERY low.
( We're currently limiting to 0.3% max.).

Also: why are assembly solder pot standards (J-STD-001) Table 5-1 (Solder
Limits) more relaxed than HAL (J-STD-006)?

Thanks,
Mark

P.S. Thanks to all who responded to my previous HAL question.

P.S. Technet's a great forum: Scientific, but not clinical.  Focused and
knowledgeable. Occasionally emotional, but moderated.

---------------------------------------------------------------------------------