Jean-François,

At 50% RH, make a ruling that you will permit no smocks on condition
that the workers wear only cotton clothing (including underclothing) --
or nothing at all, of course :-). Cotton is sufficiently hygroscopic to
present no risk, especially at high temperatures. In addition, it offers
the workers the best comfort under such conditions.

Brian

> "Bissonnette, Jean-Francois" wrote:
>
> Hi techneters
>
> Would it be considered risky to permit shop floor employees to work
> without
> ESD smocks if the humidity level is around 50%?
>
> Problem is that the temperature is very high (35 dec celcius) and
> working with
> the smock is a real torture.
>
> I hesitate before giving the my opinion on this.  I know that the
> higher the humidity
> the lower the risk of having ESD problems.  But is 50% enough???
>
> Jean-François Bissonnette
> Contrôle de la Qualité, Électronique
> Quality Control, Electronics
> Vapor Canada Inc.
> 10655 Henri-Bourassa O.
> St-Laurent, Qc
> H4S 1A1
> (514) 335-4200 Ext: 2021
>
>
> WABTEC CORPORATION CONFIDENTIALITY NOTE
> The content contained in this e-mail transmission is legally
> privileged and confidential information intended only for the use of
> the individual or entity named herein. If the reader of this
> transmission is not the intended recipient, you are hereby notified
> that any dissemination, distribution, or copying of this transmission
> is strictly prohibited.

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2