Hi all,
I have had some problems with a recent build with 0603 capacitors. The
problem was that they were either very skewed or were soldered to one pad
only (pulled off the other). The land pattern for the 0603 cap on this board
was (I thought) fairly questionable. Using the IPC-SM-782 terminology, the
current design is:
X = 1.27 (0.05")
Y = 0.508 (0.02")
G = 1.016 (0.04")
Our design dept's justification for this design is based on being able to
put a via between the pads, but to my mind the G value is too borderline for
consistent results. Also, I think the X value is a little on the high side -
hence the skewing.
I'm now trying to convince the design guys to adopt the IPC guidelines - at
least the recommended G value anyway.
I'd appreciate anybody else's thoughts on this!
Incidentally, we placed 0402s on the same board with very few problems :)

Thanks


Justin Braime

Senior Production Engineer
Thales Instruments Ltd.
480 Bath Road
Slough
SL1 6BE

Tel:    01628 604455 x 392
Fax:    01628 662017
Email:  [log in to unmask]



*******************************************************************************************************
The information contained in this e-mail is confidential. It may also be legally privileged.
It is intended only for the stated addressee(s) and access to it by any other person
is unauthorised. If you are not an addressee, you must not disclose, copy, circulate or
in any other way use or rely on the information contained in this e-mail.
Such unauthorised use may be unlawful.

If you have received this e-mail in error, please inform us immediately on
+44 (0)1628 604455 (ask for the I.T. dept) and delete it and all copies from your system.
*******************************************************************************************************

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2