Hi 'netters,

We are currently experiencing a high failure of a 6-lead RF amplifier IC
assembled on a FR4 laminate. The device itself dissipates about 3.5W, so the
power density is pretty high. The device has a heat slug on its underbelly
for thermal sinking via solder through to the solder pad (surrounded by
inductive vias) onto the PCB ground plane (mechanically interfaced to the
aluminium metal housing). The component is reflowed and subsequently the
solder seeps thru the vias. However, due to PCB design constraints and
'blind soldering', contact between the slug and the solder is inadequate.

Alternatives proposed are to have a hole in the PCB and somehow hand-apply
solder from the bottom, but the design criteria may be compromised, and as
always a quick remedy is sought without design changes. Thermal pads,
thermal paste, thermal glue, hand solder? The solution must also be
electrically as well as thermally conductive.

Any advice eagerly awaited and valued.
Grant


**********************************************************************
Notice:

The information contained in this e-mail (including any attachments) may contain commercially sensitive or confidential information which may be legally privileged and is for the sole use of the intended recipient(s). If you are not, or believe you may not be, the intended recipient, you are hereby notified that any use, dissemination, copying, review, disclosure or action taken in reliance of this e-mail is prohibited and may be unlawful. If you have received this message in error, please notify the sender immediately by reply e-mail and delete all copies of the message.

Any views expressed in this message are those of the individual sender unless expressly stated by the sender to be given on behalf of Tellumat (Pty) Ltd. Tellumat (Pty) Ltd disclaims liability for any unauthorised opinion or representation made by the sender on behalf of Tellumat (Pty) Ltd.

No warranty is given by Tellumat (Pty) Ltd that the integrity or security of this e-mail (including any attachments) has been maintained through transmission, nor that the communication is free of virus, interception or interference.

**********************************************************************

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2