Raul,

I have seen this problem and it was a lubricant suspended in parafin wax. The switch
vendor was at fault. Wrong type of lub. (It didn't really need any - gold on gold)

David A. Douthit
Manager
LoCan LLC

"Valdez, Raul (R.)" wrote:

> Hello,
> We are using rotary switch encoders on our application and they are failing,
> after some were opened, certain kind of yellow grease was found, we are not
> sure if that's flux since the encoder is being soldered to the board thru
> wave soldering.
>
> After cleaning the "defective" encoder with alcohol the encoder works fine.
>
> Anyone has had a similar experience?? soldering process or encoder supplier
> fault??
>
> Please help.
>
> Thanks.
>
> Raúl Valdéz.
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2