TECHNET Archives

August 2001

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
Michael Flett <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Sun, 19 Aug 2001 13:27:48 -0500
Content-Type:
text/plain
Parts/Attachments:
text/plain (58 lines)
On Thu, 5 Jul 2001 00:56:32 -0700, Shirley Xiao <[log in to unmask]>
wrote:

>IPC-TM-650 2.3.18 "gel time, prepreg material" 4.1
>states" Platen, hot plate or melting point apparatus
>capable of maintaining a temperature of 171.5 C +/-
>0.5 C (340 F +/- 0.9 F).
>
>Is that mean laminators need to have a thermalmeter
>with accuracy better than 0.5 C? I audited several
>plant but can not find one can meet this requirement.
>
>How big is the impact on gel time test result if gel
>plate temperature shifted?
>
>
>Regards
>Shirley
>
>__________________________________________________
>Do You Yahoo!?
>Get personalized email addresses from Yahoo! Mail
>http://personal.mail.yahoo.com/
>
>---------------------------------------------------------------------------
------
>Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
>To unsubscribe, send a message to [log in to unmask] with following text in
>the BODY (NOT the subject field): SIGNOFF Technet
>To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
>Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
>Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
>information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
>---------------------------------------------------------------------------
------

Shirley,

at this temperature, 1°c will make approx. 6 seconds difference to the gel
time. It is also my opinion that gel time should only be used for guidance
and that the most critical characteristic is minimum melt viscosity.

Regards Michael

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2