Grant,

Is the unit hermetically sealed? If so is he board baked prior to sealing and are you using dry nitrogen or something simular?

If not then moisture/contamination issues can cause problems.

David A. Douthit
Manager
LoCan LLC

Grant Emandien wrote:

> Brian,
>
> Thanks for the response - the unit operates between -40deg.C to 60deg.C
>
> -----Original Message-----
> From: Brian Ellis [mailto:[log in to unmask]]
> Sent: Wednesday, August 15, 2001 12:29 PM
> To: [log in to unmask]
> Subject: Re: [TN]
>
> Grant
>
> You have a few problems, but nothing very severe. I agree that at 5 GHz,
> "no-clean" is a no-no. However, I'd be concerned with FR-4 at those
> frequencies as the Zo of your tracks can vary considerably with
> humidity. What is unclear is whether the product operates at ONLY -40°C
> or whether at higher temps, as well. If only there, then my guess is
> that you have no specific W/S flux-related problem. A Mr. Arrhenius told
> me that you should have much reduced corrosion risks and that cleaning
> and excellent drying with adequate equipment (i.e., 10% of what is
> available on the market) will give you the required results. Ionic
> contamination testing would be adequate for process control, once you
> have established your qualification conditions.
>
> Brian
>
> Grant Emandien wrote:
> >
> > Hi all out there,
> >
> > One of our customers is concerned with the level of flux residue (no
> clean)
> > present on RF boards - concern that the flux characteristics negatively
> > affects circuit perfomance (FR4 material, HASL finished is being used for
> > circuitry operating at 5GHz). He has thus requested to rather assemble
> using
> > water-soluble flux. With water-soluble flux of course comes cleanliness
> > issues which may result in latent defects due to entrapped corrosive flux
> > residue. The product is spec'd to operate, uncoated at -40deg.C. Any
> > insights into this dilemma?
> >
> > Thanks in anticipation.
> > Grant
> >
> > **********************************************************************
> > Notice:
> >
> > The information contained in this e-mail (including any attachments) may
> contain commercially sensitive or confidential information which may be
> legally privileged and is for the sole use of the intended recipient(s). If
> you are not, or believe you may not be, the intended recipient, you are
> hereby notified that any use, dissemination, copying, review, disclosure or
> action taken in reliance of this e-mail is prohibited and may be unlawful.
> If you have received this message in error, please notify the sender
> immediately by reply e-mail and delete all copies of the message.
> >
> > Any views expressed in this message are those of the individual sender
> unless expressly stated by the sender to be given on behalf of Tellumat
> (Pty) Ltd. Tellumat (Pty) Ltd disclaims liability for any unauthorised
> opinion or representation made by the sender on behalf of Tellumat (Pty)
> Ltd.
> >
> > No warranty is given by Tellumat (Pty) Ltd that the integrity or security
> of this e-mail (including any attachments) has been maintained through
> transmission, nor that the communication is free of virus, interception or
> interference.
> >
> > **********************************************************************
> >
> >
> ----------------------------------------------------------------------------
> -----
> > Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> > To unsubscribe, send a message to [log in to unmask] with following text in
> > the BODY (NOT the subject field): SIGNOFF Technet
> > To temporarily halt delivery of Technet send the following message: SET
> Technet NOMAIL
> > Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> > Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
> additional
> > information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> >
> ----------------------------------------------------------------------------
> -----
>
> ----------------------------------------------------------------------------
> -----
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET
> Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
> E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
> ext.5315
> ----------------------------------------------------------------------------
> -----
>
> **********************************************************************
> Notice:
>
> The information contained in this e-mail (including any attachments) may contain commercially sensitive or confidential information which may be legally privileged and is for the sole use of the intended recipient(s). If you are not, or believe you may not be, the intended recipient, you are hereby notified that any use, dissemination, copying, review, disclosure or action taken in reliance of this e-mail is prohibited and may be unlawful. If you have received this message in error, please notify the sender immediately by reply e-mail and delete all copies of the message.
>
> Any views expressed in this message are those of the individual sender unless expressly stated by the sender to be given on behalf of Tellumat (Pty) Ltd. Tellumat (Pty) Ltd disclaims liability for any unauthorised opinion or representation made by the sender on behalf of Tellumat (Pty) Ltd.
>
> No warranty is given by Tellumat (Pty) Ltd that the integrity or security of this e-mail (including any attachments) has been maintained through transmission, nor that the communication is free of virus, interception or interference.
>
> **********************************************************************
>
> ---------------------------------------------------------------------------------
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
> ---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2