Brian, 

Thanks for the response - the unit operates between -40deg.C to 60deg.C



-----Original Message-----
From: Brian Ellis [mailto:[log in to unmask]]
Sent: Wednesday, August 15, 2001 12:29 PM
To: [log in to unmask]
Subject: Re: [TN]


Grant

You have a few problems, but nothing very severe. I agree that at 5 GHz,
"no-clean" is a no-no. However, I'd be concerned with FR-4 at those
frequencies as the Zo of your tracks can vary considerably with
humidity. What is unclear is whether the product operates at ONLY -40°C
or whether at higher temps, as well. If only there, then my guess is
that you have no specific W/S flux-related problem. A Mr. Arrhenius told
me that you should have much reduced corrosion risks and that cleaning
and excellent drying with adequate equipment (i.e., 10% of what is
available on the market) will give you the required results. Ionic
contamination testing would be adequate for process control, once you
have established your qualification conditions.

Brian

Grant Emandien wrote:
>
> Hi all out there,
>
> One of our customers is concerned with the level of flux residue (no
clean)
> present on RF boards - concern that the flux characteristics negatively
> affects circuit perfomance (FR4 material, HASL finished is being used for
> circuitry operating at 5GHz). He has thus requested to rather assemble
using
> water-soluble flux. With water-soluble flux of course comes cleanliness
> issues which may result in latent defects due to entrapped corrosive flux
> residue. The product is spec'd to operate, uncoated at -40deg.C. Any
> insights into this dilemma?
>
> Thanks in anticipation.
> Grant
>
> **********************************************************************
> Notice:
>
> The information contained in this e-mail (including any attachments) may
contain commercially sensitive or confidential information which may be
legally privileged and is for the sole use of the intended recipient(s). If
you are not, or believe you may not be, the intended recipient, you are
hereby notified that any use, dissemination, copying, review, disclosure or
action taken in reliance of this e-mail is prohibited and may be unlawful.
If you have received this message in error, please notify the sender
immediately by reply e-mail and delete all copies of the message.
>
> Any views expressed in this message are those of the individual sender
unless expressly stated by the sender to be given on behalf of Tellumat
(Pty) Ltd. Tellumat (Pty) Ltd disclaims liability for any unauthorised
opinion or representation made by the sender on behalf of Tellumat (Pty)
Ltd.
>
> No warranty is given by Tellumat (Pty) Ltd that the integrity or security
of this e-mail (including any attachments) has been maintained through
transmission, nor that the communication is free of virus, interception or
interference.
>
> **********************************************************************
>
>
----------------------------------------------------------------------------
-----
> Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
> To unsubscribe, send a message to [log in to unmask] with following text in
> the BODY (NOT the subject field): SIGNOFF Technet
> To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
> Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
> Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
> information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
>
----------------------------------------------------------------------------
-----

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----


**********************************************************************
Notice:

The information contained in this e-mail (including any attachments) may contain commercially sensitive or confidential information which may be legally privileged and is for the sole use of the intended recipient(s). If you are not, or believe you may not be, the intended recipient, you are hereby notified that any use, dissemination, copying, review, disclosure or action taken in reliance of this e-mail is prohibited and may be unlawful. If you have received this message in error, please notify the sender immediately by reply e-mail and delete all copies of the message.

Any views expressed in this message are those of the individual sender unless expressly stated by the sender to be given on behalf of Tellumat (Pty) Ltd. Tellumat (Pty) Ltd disclaims liability for any unauthorised opinion or representation made by the sender on behalf of Tellumat (Pty) Ltd. 

No warranty is given by Tellumat (Pty) Ltd that the integrity or security of this e-mail (including any attachments) has been maintained through transmission, nor that the communication is free of virus, interception or interference.

**********************************************************************

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2