Hi Craig,

One rework cycle for a BGA means desoldering, cleaning excessive solder from the BGA-pads, reballing and resoldering, all this in addition to the original soldering cycle.
I don't think there's any manufacturer that will guarantee that their BGA's will survive this.
In practice I've had some good results (meaning: the board still worked) with BGA's that were subjected to all these cycles for 4 or 5 times.

Kind regards,

Daan Terstegge
Unclassified mail
Personal Website: http://www.smtinfo.net 

>>> Craig Hillman <[log in to unmask]> 08/02 12:48 am >>>
Technetters,

Any recommendations on maximum number of rework cycles for a Plastic BGA?

TIA,
Craig

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2