Ken -
IPC-D-356 is a data transfer language developed by the IPC to replace
Gerber. It is a far more intelligent form of physical definition for
PCB/PWB. The only segment of the language that seems to have developed any
market support is the physical netlist that includes x, y and top, bottom
connectivity information for electrical test equipment. Some CAD systems
are capable of generating the IPC-D-356 netlist, and most fabricators have a
CAM system that can generate this data from the Gerber files.
Jeffrey A. McGlaughlin, C.I.D.
Sr. PCB Designer
Battelle Memorial Institute
Columbus Ohio
[log in to unmask]
-----Original Message-----
From: Ken Patel [mailto:[log in to unmask]]
Sent: Monday, August 06, 2001 5:38 PM
To: [log in to unmask]
Subject: [TN] IPC-D-356
Designer,
We normally put as fab note that "Use IPC-D-356 Netlist to Verify the
board before fabrication."
So, I have a question...
Is IPC-D-356 is a CAD (like Allegro/PADS) output file or something else?
re,
Ken Patel
----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|