TECHNET Archives

August 2001

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"Marsico, James" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Mon, 13 Aug 2001 07:06:58 -0400
Content-Type:
text/plain
Parts/Attachments:
text/plain (43 lines)
Yes, we do.  We have a couple of densely populated boards with a lot of
polarized capacitors.  We made a template out of .010" thick copper.   An
artwork was generated for the component locations and the copper was etched
like fabricating a stencil.  The polarity was then marked with ink on the
template.  This works rather well.  Once you generate the artwork your
stencil supplier could etch the material.  No frame is needed.

Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
631-595-5879



        -----Original Message-----
        From:   Jack Bryant [SMTP:[log in to unmask]]
        Sent:   Friday, August 10, 2001 10:21 PM
        To:     [log in to unmask]
        Subject:        [TN] Assembly Inspection/verification.

        TechNet,

        Has anyone tried to use templates or overlays at the end of a
machine process or the end of a progressive line as a quick check for
polarity or component orientations? If so what type of materials did you
make your overlays from? Were they conductive for ESD? Where did you have
your templates made? Can a board house make these from Gerber data? Stencil
shop? I would appreciate your comments. Thanks.

        J. Bryant

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2