Dear Rick Howieson,

Your question is a legitimate one indeed,

1. If you are a PCB manufacturer then, it is a Repair or Acceptance
conditions
    to be agreed between parties to become Rework.
2. If you are an Assembly house then it can be both.

3. The question left open is, by what guide are judging this defect,
    I assume that IPC standards will not accept this attitude as you have
    described, it has to be glued first...

Avigdor



-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Rick Howieson
Sent: Tuesday, July 03, 2001 5:22 PM
To: [log in to unmask]
Subject: [TN] Rework/Repair


Question: Let's say I have a pad that is slightly lifted and I'm able to
push it down. Is this considered Rework or Repair?
Thanks,
Rick Howieson

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2