Hi Ingemar,
You write:
>W,
>can't you tell a little about the 'time to maximum wetting' also? It's
>remarkable how little this is mentioned. Tx oh guru.

Should have thought of that, but since I am at my son's house and am 
distracted by my 3 granddaughters (6, 4, and 2) who all want the attention of 
their 'Opa,' I hope I am forgiven by making up for this oversight now.
Timing is indeed essential and a big part of what profiling tells you.
A widely quoted, but irrelevant, reflow parameter, the time above the Solidus 
temperature of 183°C for Sn/Pb solder (the Liquidus is the same as the 
Solidus only for the eutectic solder composition), ranges from about 75 to 95 
seconds.  However, a better and more appropriate guideline is 15 seconds at 
or above Liquidus+20°C is just adequate for soldering to copper; for 
soldering to Ni I recommend Liquidus+35°C. 
Since this has to be at the solder joint of the whole assembly heating up the 
slowest, all other SJs will see higher T's for longer times. However, other 
than  for too thin a HASL-coat, I have never seen a SJ failure due to too 
much IMC thickness. A major component manufacturer has reported that the peak 
reflow temperature for BGAs with Ni/Au  metallization had to be increased 
from 235 to 255°C to prevent interfacial separation between the Ni and the 
solder. 
You may watch for my Reliability column in Global SMT & Packaging  magazine. 

Werner Engelmaier
Engelmaier Associates, L.C.
Electronic Packaging, Interconnection and Reliability Consulting
7 Jasmine Run
Ormond Beach, FL  32174  USA
Phone: 904-437-8747, Fax: 904-437-8737
E-mail: [log in to unmask], Website: www.engelmaier.com 

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2