TECHNET Archives

June 2001

TechNet@IPC.ORG

Options: Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
From:
"<Peter George Duncan>" <[log in to unmask]>
Reply To:
TechNet E-Mail Forum.
Date:
Tue, 26 Jun 2001 12:04:44 +0800
Content-Type:
text/plain
Parts/Attachments:
text/plain (81 lines)
Graham,

Can you cut down on the number of air exchanges per hour and build a
venturi into the delivery side of the air supply. I might still cause an
increase in wind speed inside the coating room, though, but it would be a
cheap, non-energy consuming means of cooling the air.

Regards

Pete Duncan





                    Graham Naisbitt
                    <Graham.Naisbitt@CONC        To:     [log in to unmask]
                    OAT.CO.UK>                   cc:     (bcc: DUNCAN Peter/Asst Prin Engr/ST Aero/ST Group)
                    Sent by: TechNet             Subject:     [TN] Its too darn hot to work
                    <[log in to unmask]>


                    06/26/01 06:26 AM
                    Please respond to
                    "TechNet E-Mail
                    Forum."; Please
                    respond to Graham
                    Naisbitt






Hello Techies,

I wonder if anyone can come up with some good ideas for our little problem:

We now have a heatwave with the temperature at over 30 DegC in the shade
that's 86 in old money.

Our conformal coating room which is 10,000 cubic feet (that's 283.17 in new
money) is extracted at 5000 cubic feet per minute = 30 exchanges per hour.

The problem is, I cannot easily chill that amount of air without incurring
the wrath of the Euro-Environmental Lobby (we call them Eels! If you need
to figure out why, then you need to get out more)

Can anyone suggest a novel, but effective way I can chill my staff - apart
from freezing their wages of course!

What a year, first we drown then we cook - yours in anticipation Larry the
Lobster.


RegardsRegards, Graham Naisbitt

[log in to unmask]
http://www.concoat.co.uk


For instant access to Product Data Sheets register on the Tech-Shot area of
http://www.concoat.co.uk

Concoat Limited
Alasan House, Albany Park
CAMBERLEY GU16 7PH UK
Phone: +44 (0)1276 691100
Fax: +44 (0)1276 691227
Mobile: +44 (0)79 6858 2121

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2