Hello Lou,
That's a pretty tall order. +/-10% would be achievable.
If you are using FR4, the variation in dielectric constant alone would give
you a tolerance of +/- a few percent.
regards,
Phil.
Phil Dutton C.I.D.
Senior CAD Technician
IPC Certified Interconnect Designer
Tenix Defence Systems Pty Ltd
Systems Division - Adelaide
Second Avenue, Technology Park,
Mawson Lakes. SOUTH AUSTRALIA 5095
-----Original Message-----
From: Louis T Dallara [mailto:[log in to unmask]]
Sent: Wednesday, 27 June 2001 19:57
To: [log in to unmask]
Subject: Re: [DC] [pcdlist] RE: controlled impedance
Do any one know what the type tolerance is for a controlled impedance board?
+/- 1% of a 100 ohm trace??
TIA
Lou Dallara
Infincon Systems
---------------------------------------------------------------------------------