We use +/- 0.003" for all holes less than 0.064" diameter (except for special
cases such as press-fit connectors.)
Roy H. Beckman, C.E.T., C.I.D.
Senior PCB Designer
Harris Corporation
Harris Canada, Inc.
6732 - 8th Street, N.E.
Calgary, Alberta, Canada T2E 8M4
Phone: 403-295-4758
Fax: 403-295-4622
email:[log in to unmask]
-----Original Message-----
From: Luther, Brandon [mailto:[log in to unmask]]
Sent: Tuesday, June 19, 2001 7:20 AM
To: [log in to unmask]
Subject: [DC] Via hole tolerance
Good Day!
What tolerances is everybody using for vias holes?
TIA
Brandon Luther
Dataram
---------------------------------------------------------------------------------