We rely on process control for our BGA attachment. The solder paste process
is monitored for thickness and uniformity of deposits. As long as the
proper amount of paste is applied, the placement is accurate (vision
assisted) and the reflow process is in control, then there should be no
reason to x-ray, especially since x-ray will only show bridging,
mis-alignment or missing solder. We only x-ray when we have a test failure.
Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
-----Original Message-----
From: Phil Bavaro [SMTP:[log in to unmask]]
Sent: Tuesday, June 19, 2001 1:01 PM
To: [log in to unmask]
Subject: [TN] BGA Xray Inspection: 100% or SPC controlled
Here is a question that many of you have had to deal with.......
Do you xray image inspect 100% of your BGA solder connections
or
do you only process a sample of your production volumes thru xray
or
do you not require xray inspection unless a test failure occurs on
the board?
We have bgas on close to all of our boards these days and even with
inline automatic xray equipment, it is becoming a bottleneck for
production.
I hesitate to release my xray inspection control on anything but
extremely high yielding boards unless there is very high functional
test coverage to ensure that we don't let bad product out of our
facility.
I am just wondering what the rest of the industry has adopted as a
policy for this problem.
Thanks in advance.
Phil
Phillip A. Bavaro
QUALCO/\/\/\/\ Incorporated
Manufacturing Engineer, Staff
[log in to unmask]
Cell (619) 602-8644 (offsite, after hours)
Pager (619) 271-3640
Tel (619) 658-2542 Office/voice mail
Cell (619) 845-9968 (workday)
Fax (619) 658-1584
----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV
1.8d
To unsubscribe, send a message to [log in to unmask] with following
text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message:
SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources &
Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
----------------------------------------------------------------------------
-----
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|