I recently ran a few test assemblies (with immersion Ag finish, of course)
through thermal cycling (for 2nd level reliability). At the end of the
test, some of the non-soldered metal area (EMI contact) got the yellow
tarnish. When probed with a multimeter I measured significant increase in
contact resistance.
I read a lot of comments on the presence of sulfur and chlorine (or their
ionic counterparts) as being the possible root cause. My question is: what
is the chemical reaction(s) here? Are those agents attacking the Ag or the
organic co-deposited with the Ag? Does anybody know what the yellow stuff
is?
Mason Hu
---------------------------------------------------------------------------------