One possible solution would be to change your test probes from a chisel type
to one with multiple points, resembling a king's crown.
Jim Marsico
Senior Engineer
Production Engineering
EDO Electronics Systems Group
[log in to unmask] <mailto:[log in to unmask]>
-----Original Message-----
From: Dan Ratcliff 727-530-8762 [SMTP:[log in to unmask]]
Sent: Thursday, May 17, 2001 3:53 PM
To: [log in to unmask]
Subject: [TN] ICT after double sided reflow
Hey all,
We have a multilayer .062 thk blind/buried/thru via OSP PCB designed
as
a double sided reflow assembly. The assembly process went fine
until
the boards reached ICT. The board has .030 dia. testpoints with and
without .010 dia. holes. Prior to this we used .040 dia test pads
with
.010 holes which after researching the issue, we felt could be
reduced
to .030. These testpoints function as ICT probe sites and as
circuit
interconnect vias. When we tested the first PCB's we found that
because
the testpoints were not soldered the OSP was not removed from the
test
pads. As a result, the test probes (high force chisel probes) did
not
reliably penetrate through the residual OSP to make contact with the
test land. For our second attempt, we applied a 1X paste print to
the
testpoints prior to reflow. The result was that while we got a good
surface for the probe to contact, some solder and flux residue ended
up
in the holes and the test probes did not reliably penetrate the flux
residue. For the third attempt, we overprinted the paste (.040) on
the
testpoints in an attempt to create enough solder volume to fill the
hole
and create a relatively flat surface to probe without the hole
capturing
flux residue. Unfortunately due to the proximity of adjacent
features
there were some testpoints which could not be overprinted. This
resulted in improved ICT yields but still left failures. The fourth
modification was to build a new ICT fixture which had tighter
tolerances, enhanced probe types and an alignment plate. This step
addressed the difficulty of hitting the .030 test pads reliably and
produced very good results. Finally we changed the paste chemistry
by
using a differant solderpaste. This seemed to eliminate the
remaining
solder issues because the paste has a higher metal content an the
residual flux did not prevent the probes from making contact with
the
test pads. The production engineers drew the conclusion from all of
this that we can not reliably hit a .030 diameter test pad and that
all
double sided reflow designs must have testpoints without holes in
them.
This was OK when we had a microvia design. However, going forward
we
are looking at very dense double sided reflow .093 thk OSP PCB's
with
thru vias only. We lack the real estate to have a via and test land
at
separate locations in densely populated analog areas. I would like
to
hear how other folks are dealing with double sided reflow and ICT.
Is
it really necessary to avoid holes in the test lands? Is it
possible to
have reliable ICT test with .040 dia. probe sites and .010 dia.
holes in
them?
Thx in advance for your help,
Dan Ratcliff
Sr. PCB Designer
Paradyne Corporation, Largo FL
727-530-8762
----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV
1.8d
To unsubscribe, send a message to [log in to unmask] with following
text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message:
SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources &
Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or
847-509-9700 ext.5315
----------------------------------------------------------------------------
-----
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|