Does anybody have any experience using Zestron VIGON SC 200 or SC 202 to
clean populated boards?

We have recently been asked by a couple of customers to comment on the
compatibility of our parts (tantalum chip caps) with  these solvents.  The
datasheets indicate that these cleaners are designed to clean stencils and
mis-printed boards - not boards with components attached.  They claim to
remove unsoldered solder paste and also conductive adhesives.  I guess that
they mean adhesives in the uncured state but they don't explicitly exclude
cured adhesive.  Since tantalum chips use a conductive adhesive to make the
internal cathode connection, I am not too sure I want this stuff on my
parts.  I am concerned about internal damage if the solvent penetrates the
case up the leadframe egress.  Maybe I am just paranoid.

In searching the archives, I found several postings about VIGON, but most
addressed how well it cleans the boards or stencils, not any impact on
components.  I would appreciate any feedback.

Thanks
Nancy Reynolds
KEMET Electronics

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2