Especially if they're plastic-bodied BGA's, YES, unused components from a
package should be resealed with desiccant. The problem is not so much
oxidisation but atmospheric moisture absorbtion. This can happen within a
matter of hours depending on the RH of the atmosphere they're exposed to
and their sensitivity to moisture absorbtion (see reply to me earlier from
Francois).
If too much moisture is absorbed and not baked out again, the soldering
temperatures cause the moisture to vapourise. This leads to internal
weakening or physical damage to the insides of the devices, and even
delamination or explosion of the casing - a phenomenon known as
'popcorning'. JEDEC J-STD-033 tells you what you need to know in this
respect and is downloadable free from the Net.
Pete Duncan
Rick Howieson
<RHowieson@DELTAGRO To: [log in to unmask]
UPINC.COM> cc: (bcc: DUNCAN Peter/Asst Prin Engr/ST Aero/ST Group)
Sent by: TechNet Subject: [TN] BGA
<[log in to unmask]>
05/24/01 10:35 PM
Please respond to
"TechNet E-Mail
Forum."; Please
respond to Rick
Howieson
Need information on protecting BGA's not loaded. Should BGA's from a
package
not used be sealed for the next run? If so, is this because the balls
become
oxidized or ...?
Thanks,
Rick Howieson
Delta Group Electronics, Inc.
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|