Scott,

In some applications we use a Thermalloy product 4170 (for TO-220 packages)
and 4180 (for TO-218 packages).

However, we have switched most of our designs to Isostrate or Thermstrate
made by Power Devices, Inc.

Best of Luck,

Phil Nutting
Manufacturing Engineer
Kaiser Systems, Inc.

-----Original Message-----
From: Buscomb, Scott [mailto:[log in to unmask]]
Sent: Tuesday, April 03, 2001 7:30 PM
To: [log in to unmask]
Subject: [TN] Aluminium Oxide Insulators


I am looking for a manufacturer of aluminium oxide insulators for TO-220
devices. I have used them in the past but I cannot recall who made them. Any
help would be appreciated.
TIA,

Scott Buscomb
PCB Design Engineer
Colorado MicroDisplay Inc.

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2