Bob,

Was electrical monitoring performed in-situ? If you only monitor before and
after exposure (or only during dwells), you are often missing bad solder
joints, especially in ball grid arrays.

Craig

-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Bob Perkins
Sent: Tuesday, March 20, 2001 5:10 PM
To: [log in to unmask]
Subject: [TN] BGA Thermal Cycling and cold spray


Hi all,

I have a question regarding thermal cycling, a good pcb that has passed all
pretests and post tests with a typical thermal cycle.  A few PCBs were then
hit with a cold spray of -30c and then tested again, after this test a fall
out of 20%.  Are we introducing a crack by the severe thermal shock of the
cold spray or is it revealing a bad solder joint.

Thanks in advance,

Bob Perkins
SMT Process Manufacturing,
Automation Technician
Aimtronics-Delta

----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2