According to IPC-SM-782, from around 3-4% misses to less than 1%.
Reference: Figure 5-2, pg 46.
Also, see section 5.7.1, para. 5. Square pads would further reduce false
probing.
Roger M. Stoops, C.I.D., PCB Designer
Trimble
Engineering and Construction Division
5475 Kellenburger Rd.
Dayton, OH 45424-1099 USA
Ph: +01 937.233.8921 or +01 937.233.4574 ext 288
Fax: +01 937.233.7511
Lothar Thole
<Lothar.Thole@V To: [log in to unmask]
SL.COM.AU> cc:
Sent by: Subject: [TN] 32mil vs 40mil
TechNet
<[log in to unmask]
G>
03/07/01 03:02
AM
Please respond
to "TechNet
E-Mail Forum.";
Please respond
to Lothar Thole
What reduction in false probing could be expected if 32mil test pads were
replaced by 40mil pads on a 900 node HP3070 fixture?
Lothar Thole
=======================================================
Lothar Thole
Manufacturing Manager
Vision Systems - ADPRO
Second Avenue, Technology Park,
MAWSON LAKES, SA 5095,
AUSTRALIA.
tel: +61-8-8300-4747 (direct)
tel: +61-8-8300-4400 (switch)
fax: +61-8-8300-4422
mobile: +61-407-166-600
email: [log in to unmask]
web site: www.vsl.com.au/adpro
=======================================================
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for
additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
---------------------------------------------------------------------------------
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|