Yes ma'am,
agree about tricky ENIG and repair. I examined a computer, pulled out the  BGA processor and sliced it into pieces and found a wonderful design without that tricky nickel, balls soldered directly on tinned copper. Old fashioned just-copper seems to be useful still. And that BGA was not a cute thing....rather a monsterBGA! What processor? You certainly guess yourself. Use to be on inside of the box.
Ingemar


-----Original Message-----
From: Bogdan Gabi [mailto:[log in to unmask]]
Sent: den 28 februari 2001 09:53
To: [log in to unmask]
Subject: Re: [TN] Heat-sinked BGA Bridging...



Same component, same problems, but during reflow at the SRT station we own, only corner bridging.Same% of good results.

Rework is done without solder paste, only Tack flux.

We suspect also warping due to Aluminium heat sink, very heavy, glued on the base circuit of the BGA and on chip with conductive glue.

During oven reflow we had solder joint problems at first, changed the speed, got better results, but we are still fighting with this component.

May I ask what is the finish of your board and if you have SMD pads or not?

Related problem:

We work with ENIG and SMD pads, I don't know if it is the best combination, also , as Ingemar told, we are also suspecting bad finish workmanship.

The other BGA's DO NOT exhibit any problems, but only during the first reflow.

If we have to rework them and desolder the bad part, some pads look dull gray and don't cover with solder during circuit pads rework and cleaning.

Thank you,

Gaby


        ----------

        From:   Stephen R. Gregory[SMTP:[log in to unmask]]

        Reply To:       TechNet E-Mail Forum.;[log in to unmask]

        Sent:   ???? ????? 27 ?????? 2001? 23:33

        To:     [log in to unmask]

        Subject:        [TN] Heat-sinked BGA Bridging...

        Hi all!

        This topic is a "moldy-oldie", but I've started to experience bridges again

        with this TI DSP (TMS320C6201GJC200). I've been doing okay up unil recently.

        We build these boards in work orders of around 25 pieces.

        Our last run we had 7 boards bridged out of 25!! Sent the boards out to be

        reworked. I asked that they be x-rayed before and after, and to my surprise

        after looking at the x-ray images, they were all bridging in the same general

        area.

        It's a 4-row periphery BGA, and the bridges are occuring on the inner two

        rows, around the center of the part, at the same side of the part.

        What's funny, is that the vendor we use to rework the boards for us is having

        difficulty as well. We've been asking him to remove, re-ball, and re-install

        the part, they said they've been having about a 50% success rate doing

        this...they've been getting the bridges too. They have a nice full-blown SRT

        BGA rework station and do this for a living.

        I print 6-mils of paste (square apertures for the BGA), have a Conceptronic

        HVN-70 which I run:

        150     160     170     180     240

        150     160     170     180     240

        25-in. per min

        We never have had these problems before...it all started when TI put the

        heatsink into the top of the part. I've looked at our paste print and it's

        dead on, placement is dead on too, we verify that with a Ersascope.

        My question is could there be something wrong with the part? Warping causes

        bridges at the corners, right? Why would it bridge in the interior rows at

        the same general area?

        Thanks in advance!

        -Steve Gregory-

        ---------------------------------------------------------------------------------

        Technet Mail List provided as a free service by IPC using LISTSERV 1.8d

        To unsubscribe, send a message to [log in to unmask] with following text in

        the BODY (NOT the subject field): SIGNOFF Technet

        To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL

        Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives

        Please visit IPC web site ( http://www.ipc.org/html/forum.htm <http://www.ipc.org/html/forum.htm> ) for additional

        information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315

        ---------------------------------------------------------------------------------

---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2