Subject: | |
From: | |
Reply To: | TechNet E-Mail Forum. |
Date: | Wed, 7 Feb 2001 16:47:42 -0500 |
Content-Type: | text/plain |
Parts/Attachments: |
|
|
I routing a bunch of signals that need to be matched in length. So I
serpentining them _|--|_|--|_
These are all CLK signals.
(3 groups of 8 signals, group 1 - 2.5 long / group 2 - 4.5 long / group 3 -
10.1 long.)
I'm using 6mil trace width and 12mil clearance (from other signals and
itself)
These signals are all generated in the same area, so they are packed
together on the same 2 layers.
Are there any signal integrity issues I should be aware of in doing this?
(especially the 10 in. group)
Michael Kuczynski Librarian/Sr. Designer
L3 Communications 1-201-393-2122 (Ph)
Space & Navigation 1-201-393-6681 (Fax)
699 Rt. 46 E Mail Stop PL1/J8
Teterboro,NJ 07680
[log in to unmask]
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|