Revision C of the IPC-A-610 states:
Acceptable - Class 1,2,3
Weave exposure does not reduce the spacing between conductive patters below
speification minimums.
Remember the adage Form, Fit and Function. I think this is likely a
non-issue.
Guy Ramsey
American Competitiveness Institute
Senior Lab Technician / Instructor
610 362-1200 ext 107
-----Original Message-----
From: TechNet [mailto:[log in to unmask]]On Behalf Of Dave Kell
Sent: Friday, January 12, 2001 2:30 PM
To: [log in to unmask]
Subject: [TN] Flex-circuit Stiffeners
I have a customer for a high rel application that is concerned about weave
exposure on a epoxy glass stiffener.
According to IPC-610, weave exposure is not acceptable. Our material
supplier sands the material in order to meet tight thickness tolerances.
Per IPC-6013, stiffeners are to be evaluated only for mechanical support. In
addition, the circuit as supplied is allowed weave exposure if conductor
spacing is not reduced below minimum. Since a stiffener carries no
conductors, I would consider this a non-issue.
Any words of wisdom from manufacturers or assemblers welcome.
Dave Kell
Minco Products, Inc.
PLEASE NOTE: Our area code has changed
from 612 to 763.
----------------------------------------------------------------------------
-----
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET
Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases >
E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700
ext.5315
----------------------------------------------------------------------------
-----
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------
|
|
|