I have a customer for a high rel application that is concerned about weave exposure on a epoxy glass stiffener.  

According to IPC-610, weave exposure is not acceptable.  Our material supplier sands the material in order to meet tight thickness tolerances.  Per IPC-6013, stiffeners are to be evaluated only for mechanical support. In addition, the circuit as supplied is allowed weave exposure if conductor spacing is not reduced below minimum. Since a stiffener carries no conductors, I would consider this a non-issue.

Any words of wisdom from manufacturers or assemblers welcome.

Dave Kell
Minco Products, Inc.


======================================PLEASE NOTE: Our area code has changed
from 612 to 763.
======================================
---------------------------------------------------------------------------------
Technet Mail List provided as a free service by IPC using LISTSERV 1.8d
To unsubscribe, send a message to [log in to unmask] with following text in
the BODY (NOT the subject field): SIGNOFF Technet
To temporarily halt delivery of Technet send the following message: SET Technet NOMAIL
Search previous postings at: www.ipc.org > On-Line Resources & Databases > E-mail Archives
Please visit IPC web site (http://www.ipc.org/html/forum.htm) for additional
information, or contact Keach Sasamori at [log in to unmask] or 847-509-9700 ext.5315
---------------------------------------------------------------------------------

ATOM RSS1 RSS2